from .constants import * import math import smbus import time class BME680(BME680Data): def __init__(self, i2c_addr=I2C_ADDR_PRIMARY, i2c_device=None): BME680Data.__init__(self) self.i2c_addr = i2c_addr self._i2c = i2c_device if self._i2c is None: self._i2c = smbus.SMBus(1) self.chip_id = self._get_regs(CHIP_ID_ADDR, 1) if self.chip_id != CHIP_ID: raise RuntimeError("BME680 Not Found. Invalid CHIP ID: 0x{0:02x}".format(self.chip_id)) self.soft_reset() self.set_power_mode(SLEEP_MODE) self._get_calibration_data() self.set_humidity_oversample(OS_2X) self.set_pressure_oversample(OS_4X) self.set_temperature_oversample(OS_8X) self.set_filter(FILTER_SIZE_3) self.set_gas_status(ENABLE_GAS_MEAS) self.get_sensor_data() def soft_reset(self): self._set_regs(SOFT_RESET_ADDR, SOFT_RESET_CMD) time.sleep(RESET_PERIOD / 1000.0) def set_humidity_oversample(self, value): self.tph_settings.os_hum = value temp = self._get_regs(CONF_OS_H_ADDR, 1) temp &= ~OSH_MSK temp |= value << OSH_POS self._set_regs(CONF_OS_H_ADDR, temp) def set_pressure_oversample(self, value): self.tph_settings.os_pres = value temp = self._get_regs(CONF_T_P_MODE_ADDR, 1) temp &= ~OSP_MSK temp |= value << OSP_POS self._set_regs(CONF_T_P_MODE_ADDR, temp) def set_temperature_oversample(self, value): self.tph_settings.os_temp = value temp = self._get_regs(CONF_T_P_MODE_ADDR, 1) temp &= ~OST_MSK temp |= value << OST_POS self._set_regs(CONF_T_P_MODE_ADDR, temp) def set_filter(self, value): self.tph_settings.filter = value temp = self._get_regs(CONF_ODR_FILT_ADDR, 1) temp &= ~FILTER_MSK temp |= value << FILTER_POS self._set_regs(CONF_ODR_FILT_ADDR, temp) def set_gas_status(self, value): temp = self._get_regs(CONF_ODR_RUN_GAS_NBC_ADDR, 1) temp &= ~RUN_GAS_MSK temp |= (value << RUN_GAS_POS) self.gas_settings.run_gas = value def set_gas_heater_temperature(self, value): self.gas_settings.heatr_temp = value temp = self._calc_heater_resistance(self.gas_settings.heatr_temp) self._set_regs(RES_HEAT0_ADDR, temp) def set_gas_heater_duration(self, value): self.gas_settings.heatr_dur = value temp = self._calc_heater_duration(self.gas_settings.heatr_dur) self._set_regs(GAS_WAIT0_ADDR, temp) def set_power_mode(self, value, blocking=True): if value not in (SLEEP_MODE, FORCED_MODE): print("Power mode should be one of SLEEP_MODE or FORCED_MODE") self.power_mode = value temp = self._get_regs(CONF_T_P_MODE_ADDR, 1) temp &= ~ MODE_MSK temp |= self.power_mode self._set_regs(CONF_T_P_MODE_ADDR, temp) while blocking and self.get_power_mode() != self.power_mode: time.sleep(POLL_PERIOD_MS / 1000.0) def get_power_mode(self): self.power_mode = self._get_regs(CONF_T_P_MODE_ADDR, 1) return self.power_mode def set_profile_duration(self, duration): pass def get_profile_duration(self): pass def get_sensor_data(self): self.set_power_mode(FORCED_MODE) tries = 10 for x in range(10): regs = self._get_regs(FIELD0_ADDR, FIELD_LENGTH) self.data.status = regs[0] & NEW_DATA_MSK self.data.gas_index = regs[0] & GAS_INDEX_MSK self.data.meas_index = regs[1] adc_pres = (regs[2] << 12) | (regs[3] << 4) | (regs[4] >> 4) adc_temp = (regs[5] << 12) | (regs[6] << 4) | (regs[7] >> 4) adc_hum = (regs[8] << 8) | regs[9] adc_gas_res = (regs[13] << 2) | (regs[14] >> 6) gas_range = regs[14] & GAS_RANGE_MSK self.data.status |= regs[14] & GASM_VALID_MSK self.data.status |= regs[14] & HEAT_STAB_MSK if self.data.status & NEW_DATA_MSK: self.data.temperature = self._calc_temperature(adc_temp) self.ambient_temperature = self.data.temperature self.data.pressure = self._calc_pressure(adc_pres) self.data.humidity = self._calc_humidity(adc_hum) self.data.gas_resistance = self._calc_gas_resistance(adc_gas_res, gas_range) return True else: time.sleep(POLL_PERIOD_MS / 1000.0) return False def _set_regs(self, register, value): if isinstance(value, int): self._i2c.write_byte_data(self.i2c_addr, register, value) else: self._i2c.write_i2c_block_data(self.i2c_addr, register, value) def _get_regs(self, register, length): if length == 1: return self._i2c.read_byte_data(self.i2c_addr, register) else: return self._i2c.read_i2c_block_data(self.i2c_addr, register, length) def _get_calibration_data(self): calibration = self._get_regs(COEFF_ADDR1, COEFF_ADDR1_LEN) calibration += self._get_regs(COEFF_ADDR2, COEFF_ADDR2_LEN) heat_range = self._get_regs(ADDR_RES_HEAT_RANGE_ADDR, 1) heat_value = self._get_regs(ADDR_RES_HEAT_VAL_ADDR, 1) sw_error = self._get_regs(ADDR_RANGE_SW_ERR_ADDR, 1) self.calibration_data.set_from_array(calibration) self.calibration_data.set_other(heat_range, heat_value, sw_error) def _calc_temperature(self, temperature_adc): var1 = (temperature_adc / 8) - (self.calibration_data.par_t1 * 2) var2 = (var1 * self.calibration_data.par_t2) / 2048 var3 = ((var1 / 2) * (var1 / 2)) / 4096 var3 = ((var3) * (self.calibration_data.par_t3 * 16)) / 16384 # Save teperature data for pressure calculations self.calibration_data.t_fine = (var2 + var3) calc_temp = (((self.calibration_data.t_fine * 5) + 128) / 256) return calc_temp def _calc_pressure(self, pressure_adc): var1 = (self.calibration_data.t_fine / 2) - 64000 var2 = ((var1 / 4) * (var1 / 4)) / 2048 var2 = (var2 * self.calibration_data.par_p6) / 4 var2 = var2 + ((var1 * self.calibration_data.par_p5) * 2) var2 = (var2 / 4) + (self.calibration_data.par_p4 * 65536) var1 = ((var1 / 4) * (var1 / 4)) / 8192 var1 = ((var1 * (self.calibration_data.par_p3 * 32)) / 8) + ((self.calibration_data.par_p2 * var1) / 2) var1 = var1 / 262144 var1 = ((32768 + var1) * self.calibration_data.par_p1) / 32768 calc_pres = 1048576 - pressure_adc calc_pres = (calc_pres - (var2 / 4096)) * 3125 calc_pres = (calc_pres / var1) * 2 var1 = (self.calibration_data.par_p9 * (((calc_pres / 8) * (calc_pres / 8)) / 8192)) / 4096 var2 = ((calc_pres / 4) * self.calibration_data.par_p8) / 8192 var3 = ((calc_pres / 256) * (calc_pres / 256) * (calc_pres / 256) * self.calibration_data.par_p10) / 131072 calc_pres = calc_pres + ((var1 + var2 + var3 + (self.calibration_data.par_p7 * 128)) / 16) return calc_pres def _calc_humidity(self, humidity_adc): temp_scaled = ((self.calibration_data.t_fine * 5) + 128) / 256 var1 = (humidity_adc - ((self.calibration_data.par_h1 * 16))) \ - (((temp_scaled * self.calibration_data.par_h3) / (100)) / 2) var2 = (self.calibration_data.par_h2 * (((temp_scaled * self.calibration_data.par_h4) / (100)) + (((temp_scaled * ((temp_scaled * self.calibration_data.par_h5) / (100))) / 64) / (100)) + (1 * 16384))) / 1024 var3 = var1 * var2 var4 = self.calibration_data.par_h6 * 128 var4 = ((var4) + ((temp_scaled * self.calibration_data.par_h7) / (100))) / 16 var5 = ((var3 / 16384) * (var3 / 16384)) / 1024 var6 = (var4 * var5) / 2 calc_hum = (((var3 + var6) / 1024) * (1000)) / 4096 return min(max(calc_hum,0),100000) def _calc_gas_resistance(self, gas_res_adc, gas_range): var1 = ((1340 + (5 * self.calibration_data.range_sw_err)) * (lookupTable1[gas_range])) / 65536 var2 = (((gas_res_adc * 32768) - (16777216)) + var1) var3 = ((lookupTable2[gas_range] * var1) / 512) calc_gas_res = ((var3 + (var2 / 2)) / var2) return calc_gas_res def _calc_heater_resistance(self, temperature): temperature = min(max(temperature,200),400) var1 = ((self.ambient_temperature * self.calibration_data.par_gh3) / 1000) * 256 var2 = (self.calibration_data.par_gh1 + 784) * (((((self.calibration_data.par_gh2 + 154009) * temperature * 5) / 100) + 3276800) / 10) var3 = var1 + (var2 / 2) var4 = (var3 / (self.calibration_data.res_heat_range + 4)) var5 = (131 * self.calibration_data.res_heat_val) + 65536 heatr_res_x100 = (((var4 / var5) - 250) * 34) heatr_res = ((heatr_res_x100 + 50) / 100) return int(heatr_res) def _calc_heater_duration(self, duration): if duration < 0xfc0: factor = 0 while duration > 0x3f: duration /= 4 factor += 1 return int(duration + (factor * 64)) return 0xff