28ebcb63a5
Also test on Python 3.7 and 3.8 via Tox
2020-08-09 02:15:20 +02:00
b36d259ae1
Remove coveralls integration
2020-08-09 02:15:20 +02:00
efce546001
Fix compensation tests for fixed ambient_temperature on first gas reading
2020-08-09 02:15:20 +02:00
cd32ec320d
Merge upstream
2020-08-09 01:44:29 +02:00
Philip Howard
7e6bdd0dc4
Merge pull request #28 from pimoroni/tests-and-qa
...
Tests and QA
2020-03-20 15:49:53 +00:00
Phil Howard
5806466739
Fix for test in py3
2020-03-20 15:44:06 +00:00
Phil Howard
45eeba9bb4
Minor linting fixes to examples
2020-03-20 15:38:31 +00:00
Phil Howard
90fabf53fa
Expand test coverage and improve tests
2020-03-20 15:38:22 +00:00
f61ae9a86a
travis: fix build config validation problems
...
- https://docs.travis-ci.com/user/reference/overview/#deprecated-virtualization-environments
2020-02-28 13:23:20 +01:00
Philip Howard
3a48112445
Fix learn link for #25 ( #26 )
2019-11-08 11:53:07 +00:00
Sandy Macdonald
91434caf0b
Merge pull request #24 from pimoroni/examples-tidyup
...
Tidying up and adding examples
2019-06-09 13:14:58 +01:00
Sandy Macdonald
5a5dd139c3
Tidying up and adding examples
2019-06-09 13:11:35 +01:00
db4626f370
Use fixed ambient_temperature on first gas reading, it's nearly irrelevant
...
Note: on subsequent gas measurements the last temperature instead of 25 degree C will be used.
Nearly irrelevant because this happens to return value of _calc_heater_resistance(200):
ambient_temperature = 30 -> int(84.9119287004)
ambient_temperature = 25 -> int(84.9119068473)
ambient_temperature = 20 -> int(84.9118849941)
ambient_temperature = 10 -> int(84.9118412877)
2018-12-24 23:18:33 +01:00
Giampiero Baggiani
e827e5d622
added check on constants.__dict__ for micropython support ( #18 )
...
* added check on constants.__dict__ for micropython support
2018-12-10 09:55:07 +00:00
5a4709992e
Add fork description to README
2018-12-07 12:04:25 +01:00
6442510ab0
Use floating point precision for measurement compensations to yield sensor resolution
...
According to the datasheet the resolution delivered by the sensor is better
than 1 degree Celsius, 1 Pascal, 1 percent relative humidity etc. The user
should have the possibility to get floating point precision and figure out
what the measurement accuracy allows given their settings.
2018-12-07 11:39:50 +01:00
db02dd0d65
Increase poll period by x5 to allow successful measurement on max oversampling
2018-12-07 11:39:50 +01:00
c85e3de250
Remove redundant tweaking of measurement settings after soft reset, let user choose once
2018-12-07 11:39:50 +01:00
405867a4aa
Use standard units for pressure measures, let user choose conversion
2018-12-07 11:39:45 +01:00
Philip Howard
e97c5f9241
Merge pull request #17 from pimoroni/tests
...
Fixed Travis badge URL
2018-09-03 11:42:59 +01:00
Phil Howard
e43b362a33
Fixed Travis badge URL
2018-09-03 11:39:10 +01:00
Philip Howard
15171e57f6
Merge pull request #16 from pimoroni/tests
...
Test suites and code QA fixes
2018-09-03 11:17:21 +01:00
Phil Howard
8dce708fef
Check for both i2c addresses in examples
2018-09-03 11:13:32 +01:00
Phil Howard
df382a50aa
Updated badges
2018-09-02 11:31:16 +01:00
Phil Howard
6374bc4241
Test suites and code QA fixes
2018-09-02 11:26:04 +01:00
Phil Howard
c97791d720
Updated ignored QA warnings
2018-08-28 21:09:53 +01:00
Phil Howard
4b61558566
Added Build Status
2018-08-28 20:41:16 +01:00
Phil Howard
a4a0cfcd2a
Added flake8 install for travis
2018-08-28 20:33:03 +01:00
Phil Howard
b2641c48df
Travis flake8 checks
2018-08-28 20:30:59 +01:00
Phil Howard
2dc799a7a4
Added BG tooling
2018-08-14 09:30:42 +00:00
Phil Howard
50902ac08e
Prep for v1.0.5
2018-06-01 17:15:10 +01:00
Phil Howard
05f80690e0
Merge branch 'ayeks-offset'
2018-06-01 16:10:47 +01:00
Phil Howard
0f0be7f2c2
Tidied up temp-offset.py example
2018-06-01 16:10:34 +01:00
Phil Howard
4ae50e2f2c
Fixed bug in set_temp_offset
2018-06-01 16:10:08 +01:00
Phil Howard
7e08c2d749
Fixed packaging errors
2018-06-01 16:04:37 +01:00
Phil Howard
bc2f729013
Made temp-offset.py executable
2018-06-01 16:04:27 +01:00
Lars Lühr
fed191e40e
use math.copysign for temp offset calculation
2018-05-31 08:21:14 +00:00
Lars Lühr
8cb0dead6b
added temp offset float example
2018-05-28 21:41:16 +00:00
Lars Lühr
ae004aa62b
accept float values in set_temp_offset
2018-05-28 21:38:19 +00:00
Lars Lühr
1c9ba41306
added set_temp_offset function and example
2018-05-28 21:18:20 +00:00
Philip Howard
40b4b63b93
Create LICENSE
2018-02-20 15:21:25 +00:00
Phil Howard
da6ae97f1f
Prep for v1.0.4
2017-12-04 10:37:52 +00:00
Philip Howard
097287e842
Merge pull request #8 from lowflyerUK/master
...
Updated mask operation in constants.py to correct gas resistance
2017-12-04 10:28:14 +00:00
lowflyerUK
02407e1d01
Updated mask operation in constants.py to correct gas resistance
2017-12-03 21:49:32 +00:00
Phil Howard
888d8b312a
Convert negative gas resistance readings to unsigned int32
2017-12-01 14:08:40 +00:00
Phil Howard
288daed781
Version 1.0.3 prep
2017-11-23 11:25:34 +00:00
Philip Howard
c9d4cef987
Merge pull request #5 from gkluoe/master
...
Fix reassignment of variable in pressure calculation algo
2017-11-22 16:19:43 +00:00
Geoff Lee
26a28bfde7
Fix reassignment of variable in pressure calculation algo
2017-11-21 21:16:27 +00:00
Philip Howard
1baa47fb56
Merge pull request #4 from davea/typeerror_fixes
...
Fix Python 3 TypeError crashes by using floor division explicitly
2017-11-20 12:09:09 +00:00
Dave Arter
3e4bf56802
Fix Python 3 TypeError crashes by using floor division explicitly
...
The / operator in Python 3 returns a float, which was causing TypeErrors
when being passed to the << or >> operators.
2017-11-19 17:10:27 +00:00