A python library for accessing the VEML6070 digital UV light sensor from Vishay
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
cn 1bdfe0e54a module: add estimated risk level calculation based on UVA light intensity 3 weeks ago
tests module: add estimated risk level calculation based on UVA light intensity 3 weeks ago
veml6070 module: add estimated risk level calculation based on UVA light intensity 3 weeks ago
.gitignore module: add pytest for unit and snapshot testing with travis-ci 1 year ago
.pylintrc module: ignore some files for linting 1 year ago
.pyup.yml module: make pyup less noisy 7 months ago
.travis.yml module: test python 3 versions of debian on travis-ci 1 month ago
LICENSE Initial commit 3 years ago
README.md module: calculate UVA light intensity correctly for rset != RSET_240K 3 weeks ago
demo.py module: ignore some files for linting 1 year ago
pytest.ini module: add pytest for unit and snapshot testing with travis-ci 1 year ago
requirements.txt deps: update pytest from 4.5.0 to 4.6.4 3 months ago
setup.py Fiat lux 3 years ago

README.md

python-veml6070

Build Status

A Python library for accessing the VEML6070 digital UV light sensor from Vishay via python-smbus using the I2C interface.

Default settings are suitable for Raspberry Pi 2 and 3 and was successfully tested using a breakout.

I created this Python library in style of e.g. python-tsl2591 (of the TSL2591 light sensor) since I found either python code broken for my hardware or code targeted at Arduino.

Usage

Consult the datasheet, the application notes and see demo.py for clues how to use this library.

Not all functions of the chip are supported, especially not the interrupt handling since I had no use for this. Please send pull requests for improvements and bug fixes!

Serious Flaws before September 2019

In September 2019 it was discovered (and fixed) that:

  • previously the sensor was never shutdown between measurements which wastes power but still takes measurements successfully
  • the UVA light intensity was calculated wrongly (too high) for rset != RSET_240K due to wrong compensation: higher rset leads to higher sampling time leads to higher absolute ADC step counts which should lead to every ADC step indicating a smaller amount of W/(m*m) of UVA power and a higher precision of the final UVA power but it wrongly behaved the opposite way. The integration_time worked correctly all the time.

License

Python files in this repository are released under the MIT license.