mirror of
https://github.com/cmur2/python-bme680.git
synced 2024-12-22 12:54:29 +01:00
Ensure set_gas_heater_temperature calls _set_regs with int
When running the `examples/read-all.py` script I was seeing a crash because the value passed to `write_i2c_block_data` wasn't being converted to an int: ``` File "/home/pi/tmp/bme680/library/bme680/__init__.py", line 281, in _set_regs self._i2c.write_i2c_block_data(self.i2c_addr, register, value) TypeError: Third argument must be a list of at least one, but not more than 32 integers ``` This commit ensures `set_gas_heater_temperature` converts the temperature to an int before it's passed to `self._set_regs`.
This commit is contained in:
parent
44208f5dae
commit
35b26a1529
@ -182,7 +182,7 @@ class BME680(BME680Data):
|
||||
raise ValueError("Profile '{}' should be between {} and {}".format(nb_profile, NBCONV_MIN, NBCONV_MAX))
|
||||
|
||||
self.gas_settings.heatr_temp = value
|
||||
temp = self._calc_heater_resistance(self.gas_settings.heatr_temp)
|
||||
temp = int(self._calc_heater_resistance(self.gas_settings.heatr_temp))
|
||||
self._set_regs(RES_HEAT0_ADDR + nb_profile, temp)
|
||||
|
||||
def set_gas_heater_duration(self, value, nb_profile=0):
|
||||
|
Loading…
Reference in New Issue